EN50131

This European standard specifies the requirements for intrusion and hold-up alarm systems (EMA/ÜMA) installed in buildings that use exclusive or non-exclusive wired connections or wireless connections. The standard does not contain requirements for EMA/ÜMA for outdoor use. These requirements also apply to components of EMA/ÜMA installed in buildings that are usually mounted outdoors (for example, additional operating devices or signaling devices). This standard specifies performance requirements for installed EMA/ÜMA but contains no requirements for design, planning, installation, operation or maintenance. These requirements also apply to EMA/ÜMA that share means of detection, triggering, connection, control, communication and power supplies with other applications. The operation of EMA/ÜMA must not be adversely affected by other applications. Requirements for EMA/ÜMA components are specified according to environmental classes. This classification describes the environmental conditions under which proper operation of EMA/ÜMA components can be expected. If the requirements of the four environmental classes are not sufficient due to extreme conditions that are known to occur in certain geographic areas, the special national conditions listed in Annex A apply. This consolidated version includes amendments A1, A2 and A3.

Amendment notes

Compared with DIN EN 50131-1 (VDE 0830-2-1):2017-12, the following changes have been made: a) Update of the normative references; b) Addition and expansion of subclauses 3.1 "Terms" and 3.2 "Abbreviations"; c) Removal of the requirement to detect range reduction for Grade 4 motion detectors; d) Adjustment of the access level requirements; e) Adjustment of the time requirements for monitoring the replacement of information; f) Adjustment of the connection requirements and extension to include the principle of enforced sequence; g) Adjustment of the requirements for power supplies; h) Adjustment of Annex B on requirements for remote access to the EMA/ÜMA system; i) Addition of Annex C "Common IT security threats"; j) Further minor corrective measures; k) The German version was adapted to the current standard texts in clauses 2 and 3.