The new FireProtect 2 AC from Ajax Systems warns of various hazards, can be used in many ways and is particularly easy to install. It runs on mains power and communicates wirelessly.

Ajax Systems is launching the FireProtect 2 AC in five different versions:

  • FireProtect 2 AC (Heat/Smoke/CO): wireless, mains-powered fire detector with heat, smoke and CO sensors
  • FireProtect 2 AC (Heat/Smoke): wireless, mains-powered fire detector with heat and smoke sensors
  • FireProtect 2 AC (Heat/CO): wireless, mains-powered fire detector with heat and CO sensors
  • FireProtect 2 AC (Heat): wireless, mains-powered fire detector with heat sensor
  • FireProtect 2 AC (CO): wireless, mains-powered fire detector with CO sensor

Compatible with Various Standards

The new FireProtect 2 AC fire detectors comply with the following standards:

  • EN 14604:2005/AC:2008
  • EN 50291-1:2018
  • EN 54-5:2017+A1:2018
  • BS 5839 (part 6, grade D1)
  • UL 268 / CAN/ULC S529 — in preparation
  • UL 2075 / CAN/ULC S588 — in preparation

The fire detectors operate on a mains voltage of 110 to 240 volts and can therefore be used in various countries, such as Germany, the Netherlands, the USA or the United Kingdom.

New Housing

The FireProtect 2 AC fire detectors feature all the characteristic features of the FireProtect 2. The patented smoke chamber is dust-tight and requires no regular cleaning. Two Class A1R thermistors detect heat that may indicate a fire. The built-in carbon monoxide sensor detects hazardous carbon monoxide levels in the air. Each fire detector is equipped with a powerful 85 dB siren to warn of various types of fire hazards or other security-relevant events. Depending on the hazard, a different type of alarm is triggered. This enables appropriate action to be taken.

Mains Power Supply with Battery Backup

The 2 AC fire detectors are supplied with AC power from 110 V to 240 V and feature a sealed battery as backup. This keeps the detector operating even during a power outage and ensures fast and reliable fire detection. The service life is 10 years.

Convenient and Simple Installation

The SmartBracket mounting plate of the fire detector has been completely redesigned and allows for convenient installation. It consists of a mounting base and a protective cover, so that direct contact with the electrical wiring is prevented. The WAGO 221 connectors are located inside the SmartBracket and can be easily removed and replaced during connection. SmartBracket also offers additional space to replace the connections with larger ones if needed. Installation takes place within 90 seconds, without opening the housing and without a screwdriver.

Further Improved Wireless Connection

The FireProtect 2 AC fire detectors offer an improved networked fire alarm function. In addition to the primary connection via the Ajax alarm system, new fire detectors, as well as the alarm hub, can monitor the encrypted radio channel and activate a fire alarm directly from detector to detector. Such a function is mandatory in the United Kingdom and Australia.

A backup connection provides additional security in conjunction with the primary connection via the alarm hub. Both connections operate in parallel. If one of the fire detectors in the system detects a hazard, it sends an alarm to the alarm hub via the primary connection using the Jeweller radio protocol. The alarm hub triggers a networked alarm within 20 seconds. This is three times faster than required by EN 14604. All required information is immediately available in the Ajax apps:

  • The location of the triggering detector
  • The type of fire alarm
  • The exact alarm time.

At the same time, the triggering detector activates the backup connection and sends the alarm directly to other fire detectors. Even in the worst case, if the connection to the alarm hub is lost, the networked fire alarm is activated within one minute. There is therefore no risk of missing a fire alarm.

A networked fire alarm can also be activated by pressing the ManualCallPoint, a wireless, wall-mounted button for manual fire alarm activation.

Integration into the Ajax System Ecosystem

FireProtect 2 AC is part of the Ajax system ecosystem. Every element of the ecosystem features self-monitoring. The device exchanges data with the alarm hub over a distance of up to 1,700 meters using the Jeweller radio protocol. The alarm hub communicates with the Ajax Cloud and can thus provide real-time information for various Ajax apps. The status of the devices is continuously monitored by the Ajax system.

As part of the Ajax system ecosystem, fire detectors can interact with various other components such as surveillance cameras and PhOD detectors from the MotionCam series. A fire alarm can trigger various responses, for example switching off the alarm source, opening emergency exits or activating emergency lighting. At the same time, MotionCam (PhOD) or Ajax surveillance cameras offer the option of visual verification in the apps to identify the cause of the alarm.

Available for Order Soon

All models of FireProtect 2 AC will be available to order in Q4 2023 from authorized partners of Ajax Systems, such as German Protect.

Do you have questions about the FireProtect 2 AC fire detectors or other components in the field of security technology? Then feel free to contact us. Our security experts at German Protect look forward to hearing from you.