How is a fire warning system installed, and what value does it offer?

With this question, we are starting a new report on fire protection in the German Protect security magazine.

We show you our own real fire protection projects and take you along to the construction site.

You will see how we plan, install and commission fire warning systems. The kickoff takes us to Speyer.
There, we are installing an Ajax EN 54 fire warning system with over 70 EN 54-certified wireless smoke detectors for the DRK (German Red Cross).

As a certified Ajax Systems partner for EN 54 fire warning systems, German Protect and German Protect Secura give you an inside look at the ongoing installation. In the first video, you can see Diogo Loureiro installing the fire warning control panel. We also show you which smoke detectors are being used in this project.

 

 

How we set up the fire warning system and ensure fire alarm coverage on every floor

In the next episode of our report, we will show you step by step how a fire warning system is set up.
At the DRK in Speyer, you can see how we mount the wireless smoke detectors, manual call points and wireless sounders, connect them to the control panel, and check how they work together during commissioning.

Especially in publicly accessible buildings, the system must match the fire protection concept. The smoke detectors detect smoke automatically.
Anyone who discovers smoke or fire themselves can trigger an alarm immediately using the red Ajax ManualCallPoint (Red) Jeweller manual call point.
In the report, we show where we mount the call points and how the control panel displays a manual activation.

To ensure the warning can be perceived on every floor, we use the Ajax EN54 FireProtect (Sounder/VAD) Jeweller.
The wireless sounder warns with a siren tone and a visible flashing signal. When choosing the placement, we also take restroom areas into account.
Anyone in a toilet stall must be able to hear the alarm even when the door is closed.
The flashing signal is especially important for deaf and hard-of-hearing people, so they can recognize the warning in time and leave the building via the designated escape routes.

What is the difference between a fire warning system and a fire alarm system?

Both systems warn the people in the building. An important difference lies in how the fire department is alerted and what happens in the event of a false alarm.

A fire alarm system with a direct connection to the fire department automatically transmits the alarm to the fire department.
For example, if a technical fault triggers a fire alarm, the fire department may already be on its way before the cause is determined on site.
Depending on the cause and local regulations, the operator may be charged for the costs of this fire department deployment.

A fire warning system with alarm monitoring connection to an emergency and service control center also triggers the alarm in the building immediately.
At the same time, the control center receives the message and checks it according to the agreed alarm plan.
If it clearly identifies a false alarm, an unnecessary fire department deployment can be avoided.
In the event of a fire or an unclear situation, the control center immediately alerts the fire department.

Less cabling, lower costs for purchase and installation

If the responsible fire department considers a fire warning system suitable for the fire protection of a building, the Ajax EN 54 fire warning system opens up new possibilities.
Planning also includes the question of whether a sprinkler system is required.
Fire alarm systems are often planned together with sprinkler systems. I
f no sprinkler system is required, an EN 54 fire warning system can be a suitable solution, depending on the fire protection concept.

The Ajax EN 54 fire warning system closes the gap between simple fire warning solutions and complex wired fire alarm systems.
Its added value lies in the combination of EN 54-certified components and wireless technology.
Smoke detectors, manual call points and sounders are connected to the control panel wirelessly. This eliminates the need to run cables to the individual devices.

The difference becomes tangible in our project in Speyer. For the more than 70 wireless smoke detectors alone, we did not have to run any cables.
Especially when retrofitting existing buildings, this saves installation time and reduces intrusion into walls and ceilings.
Depending on the building, the costs for purchase and installation can be around 50 percent lower than for a comparable wired fire alarm system.

This makes the wireless solution particularly interesting for hotels, commercial properties, schools, kindergartens, nightclubs and public buildings.
Where the fire protection concept permits a fire warning system, fire protection can be implemented with significantly less installation effort.

Follow our fire protection report on the installation of the EN 54 fire warning system from Ajax Systems in our security magazine and on our YouTube channel German Protect.
Subscribe to our channel so you don't miss the next episode.

Do you need an EN 54-certified fire warning system for your property? 


Contact us at German Protect and German Protect Secura.
As a certified Ajax Systems partner for the EN 54 fire warning system in Germany, we would be happy to advise you and plan the system to suit your building.

 

 

We look forward to your inquiry

If possible, please send us images of your project so that our technicians can get a picture of your local conditions

If possible, please send us architectural plans or drawings of your project so that our technicians can get a picture of your local conditions